Dow Filmtec TW30-2521
Reverse Osmosis (RO) Membrane
325 GPD light industrial / commercial / whole house replacement reverse osmosis (RO) membrane element
Specifications: |
Membrane Type: | Polyamide Thin-Film Composite (TFC) |
Maximum Operating Temperature: | 113F (45C) |
Maximum Operating Pressure: | 600 psi (41 bar) |
Maximum Feed Flow Rate: | 6.0 gpm (1.4 m3/hr) |
pH Range, Continuous Operation: | 2-11*** |
pH Range, Short-Term Cleaning: | 1-13* (30min) |
Maximum Feed Silt Density Index: | 5 SDI |
Free Chlorine Tolerance: | < 0.1 ppm** |
Permeate Flow Rate: | 325 GPD (1.23 m3/day)* |
Stabilized Salt Rejection: | 99.5% |
*Permeate flow rate and salt rejection based on the following test conditions: 2000 ppm NaCl, 225 psig (15.5 bar), 77F (25C), 5% recovery.
Permeate flow rates for individual elements may vary +/-20%.
**Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. Since oxidation damage is not covered under warranty, Dow recommends removing residual free chlorine by pretreatment prior to membrane exposure. Most RO systems have carbon pre-filters for this purpose.
***Maximum temperature for continuous operation above pH 10 is 95F (35C).
|
|
|
Dimensions:
A: 21.0" (533mm)
B: 1.19" (30mm)
C: 0.75" (19mm)
D: 2.4" (61mm)
|
|
Model |
Diameter Inches |
Length Inches |
Active Surface Area ft2 (m2) |
Test Pressure |
Permeate Flow Capacity GPD (m3/day) |
Price (w/ Free Shipping) |
Filmtec TW30-2521 Our Stock #7030252100 Dow Part #80641 |
2.5 |
21 |
13 (1.2) |
225 psi |
325 (1.23) |
|
Notice: The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water. Effective cyst and pathogen reduction is dependent on the complete system design and on the operation and maintenance of the system.